Print Report | Back to Sample Detail

Sample Record for 2024-10-09-12

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000601 DEA: 041X7204 EFIS: 0424000430 QA Service Level: 1
DIST-CO-RTE-PM: 04-CC-580-6.22/6.22
Work Description:
Location Description:
Contractor Name: AMERICAN CIVIL CONSTRUCTORS (Claudio Roman))
Contractor Address: 3701 MALLARD DRIVE, BENICIA CA 94510
Resident Engineer: Behzad Halali Structure Rep.: Eric Racadag

Sample Information

DIME Sample ID: 2024-10-09-12
TL Number from the TL Form:
Sample Submitted By Organization: CT SC - 3672 - Richmond
Sample Organization Contact: (510) 231-7108
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 10/09/2024
Date that the sample was received by the laboratory/organization performing the testing: 10/09/2024
The quantity of what the sample constitutes: 1.5
A brief description of the sample: Rapid Strength Concrete from deck pour
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier: 28-0100
Structure name: Richmond-San Rafael Bridge
The fabricator/manufacturer/facility name: ACC

Material Information

The concrete mix design number: 21005A
The truck number from where the sample was collected: 24 7840
The batch plant ticket number from where the sample was collected: 24 7840
Concrete batch plant: ACC Volumetric Mixer
The fabricator/manufacturer designation for the sample: CTS - 1" x #4
A detailed description of where the material sample was collected: Pier 21.7 Upper Deck
Where the material sample would have been placed if not sampled: bridge deck
From Lot No.: JB3E01H31
Bag Lot No.:

Test Results

Test 1 of 2

DIME Test ID: 2024-10-09-12-3
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 10/30/2024
Date Tested: 10/30/2024
Submitted By Organization: CT HQ - Vallejo Field Laboratory
Organization Address: 690 Walnut,
Organization City: vallejo
Organization State: CA
Organization Zipcode: 94592
Organization Email: yannick.aranas@dot.ca.gov
Organization Phone: (916) 639-4315
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 3.95 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.25 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 4180 psi
Maximum load on cylinder 1 57570 lb
Maximum load on cylinder 2 56901 lb
Maximum load on cylinder 3 43240 lb
Compressive strength of cylinder 1 4534.2 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 4598.5 psi
Compressive strength of cylinder 3 3405.5 psi
Type of fracture pattern of cylinder 2 3
Type of fracture pattern of cylinder 3 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 0.99
Correction factor for cylinder 2 0.99
Correction factor for cylinder 3 0.99
Age of specimen 21 days
Age of specimen in hours no data

Test 2 of 2

DIME Test ID: 2024-10-09-12-4
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 11/13/2024
Date Tested: 11/12/2024
Submitted By Organization: CT HQ - Vallejo Field Laboratory
Organization Address: 690 Walnut,
Organization City: vallejo
Organization State: CA
Organization Zipcode: 94592
Organization Email: yannick.aranas@dot.ca.gov
Organization Phone: (916) 639-4315
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 4910 psi
Maximum load on cylinder 1 67500 lb
Maximum load on cylinder 2 62598 lb
Maximum load on cylinder 3 58450 lb
Compressive strength of cylinder 1 5208.8 psi
Type of fracture pattern of cylinder 1 3
Compressive strength of cylinder 2 4930.2 psi
Compressive strength of cylinder 3 4603.5 psi
Type of fracture pattern of cylinder 2 3
Type of fracture pattern of cylinder 3 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 0.97
Correction factor for cylinder 2 0.99
Correction factor for cylinder 3 0.99
Age of specimen 34 days
Age of specimen in hours no data

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2024-10-09-12-1ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens10/09/202410/16/2024Eric RacadagCT HQ - Sacramento Concrete Testing Laboratory
2024-10-09-12-2ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens10/09/202411/06/2024Eric RacadagCT HQ - Sacramento Concrete Testing Laboratory