Print Report | Back to Sample Detail

Sample Record for 2024-10-04-52

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000187 DEA: 112N1674 EFIS: 1122000280 QA Service Level: 1
DIST-CO-RTE-PM: 11-IMP-86-R34.8/64.1
Work Description: POLYESTER CONCRETE OVERLAY, APPLY METHACRYLATE,& JOINT SEALS.
Location Description: IMPERIAL COUNTY AT VARIOUS LOCATIONS FROM TRIFOLIUM CANAL BRIDGE (58-0017) TO GODETIA DITCH BRIDGE (58-0067)
Contractor Name: TRUESDELL CORPORATION OF CALIFORNIA, INC.
Contractor Address: 1310 W 23RD ST, TEMPE AZ 85282
Resident Engineer: Guillermo Sillas Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-10-04-52
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: Polyester
Sample Taken Date: 10/04/2024
Date that the sample was received by the laboratory/organization performing the testing: 10/07/2024
The quantity of what the sample constitutes: 2 tankers
A brief description of the sample: 1 gallon can / PPC 1121 RESIN
From where was the sample collected: Source
Laboratory sample identification: 000137KBP
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers, Benicia

Material Information

Mfg. Lot Number(s): AZ4I01484
Batch number: AZ4I01484
Mix number: AZ4I01484

Test Results

Test 1 of 6

DIME Test ID: 2024-10-04-52-1
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Verified Date: 12/30/2024
Date Tested: 10/10/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test: Accepted Vendor's Results
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens tested 6
Conditioning procedure 18/25/50+5/70
Speed of testing 0.45 in/min
Sample 1 Width 0.486 in
Sample 1 Ultimate strength 3179 psi
Sample 1 Thickness 0.26 in
Sample 1 Area 0.1264 in^2
Sample 1 Ultimate Strength Actual 401.826 lbs
Sample 1 percent elongation 78.8 %
Sample 1 Time no data0 MM:SS
Sample 2 Width 0.486 in
Sample 2 Thickness 0.266 in
Sample 2 Area 0.1293 in^2
Sample 2 Ultimate strength 2817 psi
Sample 2 Ultimate Strength Actual 364.238 lbs
Sample 2 percent elongation 68.9 %
Sample 2 Time no data0 MM:SS
Sample 3 Width 0.486 in
Sample 3 Thickness 0.26 in
Sample 3 Area 0.1264 in^2
Sample 3 Ultimate strength 2749 psi
Sample 3 Ultimate Strength Actual 347.474 lbs
Sample 3 percent elongation 66.5 %
Sample 3 Time no data0 MM:SS
Sample 4 Width 0.486 in
Sample 4 Thickness 0.265 in
Sample 4 Area 0.1288 in^2
Sample 4 Ultimate strength 3003 psi
Sample 4 Ultimate Strength Actual 386.786 lbs
Sample 4 percent elongation 74.8 %
Sample 4 Time no data0 MM:SS
Sample 5 Width 0.486 in
Sample 5 Thickness 0.259 in
Sample 5 Area 0.1259 in^2
Sample 5 Ultimate strength 2872 psi
Sample 5 Ultimate Strength Actual 361.585 lbs
Sample 5 percent elongation 70.3 %
Sample 5 Time no data0 MM:SS
Sample 6 Width 0.485 in
Sample 6 Thickness 0.257 in
Sample 6 Area 0.1246 in^2
Sample 6 Ultimate strength 3265 psi
Sample 6 Ultimate Strength Actual 406.819 lbs
Sample 6 percent elongation 80.1 %
Sample 6 Time no data0 MM:SS
Ultimate Strength Average 2981 psi
Percent Elongation Average 73 %

Test 2 of 6

DIME Test ID: 2024-10-04-52-2
Test Method: CTM 551-August 2012: Method of Test for Determining Suitability of Materials for Overlayment and Repair of Portland Cement Concrete Pavements and Structures
Verified Date: 12/30/2024
Date Tested: 10/09/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test: Accepted Vendor's Results
Test Result Compliance: complies
Additional Comments When Verified:
Curing history for Sample 1 24hr
Maximum applied load (P) for Sample 1 598.74 lb
Span length for Sample 1 9 in
Break location for Sample 1 bond
Specimen defects/notes for Sample 1 no data
Surface type for Sample 1 SSD
Modulus of rupture (R) for Sample 1 299.37 psi
Curing history for Sample 2 24hr
Maximum applied load (P) for Sample 2 1959.5 lb
Span length for Sample 2 9 in
Break location for Sample 2 bond
Specimen defects/notes for Sample 2 no data
Surface type for Sample 2 SSD
Modulus of rupture (R) for Sample 2 979.751 psi
Curing history for Sample 3 24hr
Maximum applied load (P) for Sample 3 1794.17 lb
Span length for Sample 3 9 in
Break location for Sample 3 bond
Specimen defects/notes for Sample 3 no data
Surface type for Sample 3 SSD
Modulus of rupture (R) for Sample 3 897.083 psi

Test 3 of 6

DIME Test ID: 2024-10-04-52-3
Test Method: SCAQMD 309-91-Feb93: Determination of Static Volatile Emissions
Verified Date: 12/30/2024
Date Tested: 10/08/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test: Accepted Vendor's Results
Test Result Compliance: complies
Additional Comments When Verified:
Diameter of lid 153.9 mm
Room Temperature 78 f
Tare weight no data
Initial weight 100.048 grams
Weight at 5 minutes 99.983 grams
Weight at 10 minutes 99.916 grams
Weight at 15 minutes 99.848 grams
Weight at 20 minutes 99.778 grams
Weight at 25 minutes 99.71 grams
Weight at 30 minutes 99.64 grams
Final weight 99.64 grams
Total weight loss 0.41 grams
Calculated radius of gallon can lid in cm 7.695 cm
Lid Factor 53.757 m^2
Volatile emission 21.933 grams/m^2

Test 4 of 6

DIME Test ID: 2024-10-04-52-4
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Verified Date: 05/02/2025
Date Tested: 04/28/2025
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Viscosity 93

Test 5 of 6

DIME Test ID: 2024-10-04-52-5
Test Method: ASTM D1475-Nov13: Standard Test Method For Density of Liquid Coatings, Inks, and Related Products
Verified Date: 05/02/2025
Date Tested: 04/28/2025
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Density Units pounds/gallons
Liquid Density (pounds per gallon) 9

Test 6 of 6

DIME Test ID: 2024-10-04-52-6
Test Method: ASTM D2369-Jul10: Standard Test Method for Volatile Content of Coatings
Verified Date: 05/02/2025
Date Tested: 04/28/2025
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Mean of two volatile content determination 45