Print Report | Back to Sample Detail

Sample Record for 2024-08-27-104

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000061 DEA: 051Q4804 EFIS: 0523000036 QA Service Level: 1
DIST-CO-RTE-PM: 05-SCR-1-R5.0/8.9
Work Description: RHMA OVERLAY, STRIPING AND MODIFY TRAFFIC STATIONS.
Location Description: SANTA CRUZ COUNTY FROM 0.9 MILE NORTH OF BUENA VISTA DRIVE UNDERCROSSING TO 0.2 MILE SOUTH OF RIO DEL MAR OVERCROSSING
Contractor Name: GRANITE ROCK COMPANY
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-08-27-104
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Dispute Resolution
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/27/2024
Date that the sample was received by the laboratory/organization performing the testing: 10/07/2024
The quantity of what the sample constitutes: 6 Boxes 3/4" HMA-A
A brief description of the sample: 3/4" HMA-A, WMA
From where was the sample collected: Job Site
Laboratory sample identification: 024-072
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Graniterock Aromas Drum

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number:
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 3

DIME Test ID: 2024-08-27-104-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 10/09/2024
Date Tested: 10/09/2024
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of tests 2
What is the unit of measurement for theoretical density? SI Units
Mass Determination Water
Method Performed Mechanical Agitation - Method A
Mass of oven-dry sample in air for Sample 1 2739.1 grams
Mass of sample in water for Sample 1 1683.6 grams
Mass of oven-dry sample in air for Sample 2 2629.3 grams
Mass of sample in water for Sample 2 1615 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.595
Specific Gravity for Sample 2 2.592
Average Specific Gravity 2.594
Theoretical maximum density at 25°C (77°F) 2586.5 kg/m^3

Test 2 of 3

DIME Test ID: 2024-08-27-104-2
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 10/09/2024
Date Tested: 10/09/2024
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Bulk Specific Gravity 2.548
Bulk Specific Gravity 2 2.548
Bulk Specific Gravity 3 2.551
Average Bulk Specific Gravity 2.549

Test 3 of 3

DIME Test ID: 2024-08-27-104-3
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 10/09/2024
Date Tested: 10/09/2024
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified:
Percent Air Voids 1.8 %
Percent Air Voids 2 1.8 %
Percent Air Voids 3 1.7 %
Average Percent Air Voids 1.8 %