Print Report | Back to Sample Detail

Sample Record for 2024-10-07-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-10-07-4
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 10/07/2024
Date that the sample was received by the laboratory/organization performing the testing: 10/07/2024
The quantity of what the sample constitutes: 800
A brief description of the sample: Anchor Bolts
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Universal Industrial Sales, Inc

Material Information

Rocap Number(s): na
Heat Number(s): 1201059073
Nut Mfg. Lot Number(s): na
Washer Mfg. Lot Number(s): na
Bolt Specification: ASTM F1554 -55 S1
Bolt Length(s): 5-0"
Nut Specification: na
Washer Specification: na
Finish: Plain/HDG
Diameter/Size: 2.0"
Bolt Mfg. Lot Number: na
Rocap Test Requirement(s): na
Lubricant Requirements(s): na
Washer Inner Diameter(s):

Test Results

Test 1 of 4

DIME Test ID: 2024-10-07-4-1
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 12/10/2024
Date Tested: 12/09/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) 120159073
Mfg. Lot Number no data
Finish Coating Plain
Product Markings no data
Size 2 in
Bolt Length 60 in
Measurement Average 6.5 mils

Test 2 of 4

DIME Test ID: 2024-10-07-4-2
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 12/10/2024
Date Tested: 12/09/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) 120159073
Mfg. Lot Number no data
Finish Coating Plain
Product Markings no data
Size 2 in
Bolt Length 60 in
Measurement Average 7.2 mils

Test 3 of 4

DIME Test ID: 2024-10-07-4-3
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 12/10/2024
Date Tested: 12/09/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) 120159073
Mfg. Lot Number no data
Finish Coating Plain
Product Markings no data
Size 2 in
Bolt Length 60 in
Measurement Average 7.2 mils

Test 4 of 4

DIME Test ID: 2024-10-07-4-4
Test Method: ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Reduced Tensile)
Verified Date: 12/10/2024
Date Tested: 12/10/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 3
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
1A120105907322.557768815360000Atlas
1B120105907322.557852826600000Atlas
1C120105907322.557764838680000Atlas
UTM NA
Temperature 0 f

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2024-10-07-4-5ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)12/10/2024Not scheduledAndrew AuvinenCT HQ - Sacramento Structural Materials Testing Laboratory
2024-10-07-4-6ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Tensile, Yield and Elongation)12/10/2024Not scheduledAndrew AuvinenCT HQ - Sacramento Structural Materials Testing Laboratory