Print Report | Back to Sample Detail

Sample Record for 2024-09-10-103

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993119 DEA: 021J7104 EFIS: 0220000120 QA Service Level: 1
DIST-CO-RTE-PM: 02-TRI-3-29.77/L30.88
Work Description: TRINITY 3 PAVEMENT AND DRAINAGE
Location Description: TRINITY COUNTY NEAR DOUGLAS CITY FROM READING CREEK BRIDGE TO ROUTE 299
Contractor Name: TULLIS, INC.
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Joseph Porra

Sample Information

DIME Sample ID: 2024-09-10-103
TL Number from the TL Form: 858076
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Production Start-Up
Type of Material: Hot Mix Asphalt
Sample Taken Date: 09/10/2024
Date that the sample was received by the laboratory/organization performing the testing: 09/10/2024
The quantity of what the sample constitutes: 16 Boxes
A brief description of the sample: 1/2" RHMA-G
From where was the sample collected: Manufacturer
Laboratory sample identification: D79716
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Tullis Inc - Northstate Asphalt - Redding, CA

Material Information

HMA Type: RHMA-G
HMA Grading: 1/2 inch
Lot number:
Sublot number:
HMA Mix Number:
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test

DIME Test ID: 2024-09-10-103-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 10/07/2024
Date Tested: 10/07/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Gmm=2.414
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? SI Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 7332.3 grams
Mass of oven-dry sample in air for Sample 1 1576.1 grams
Mass of container filled with the sample and water for Sample 1 8255.5 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.414
Theoretical maximum density at 25°C (77°F) 2407 kg/m^3

Test

DIME Test ID: 2024-09-10-103-2
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 10/07/2024
Date Tested: 09/12/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Gmb=2.325
Test Result Compliance: not applicable
Additional Comments When Verified:
Bulk Specific Gravity 2.327
Bulk Specific Gravity 2 2.323
Bulk Specific Gravity 3 2.325
Average Bulk Specific Gravity 2.325

Test

DIME Test ID: 2024-09-10-103-3
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 10/07/2024
Date Tested: 09/13/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Pa=3.7
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids 3.6 %
Percent Air Voids 2 3.8 %
Percent Air Voids 3 3.7 %
Average Percent Air Voids 3.7 %

Test

DIME Test ID: 2024-09-10-103-4
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 10/07/2024
Date Tested: 09/26/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Pb=7.98
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 3034.4 g
Mass of the specimen and specimen basket assembly prior to ignition 4621 g
Mass of HMA Sample prior to ignition 1586.6 g
Corrected Asphalt Binder Content 7.98 %
Mass Loss 137.4 g
Mass of aggregate remaining after ignition 1449.2 g
Correction Factor (Percent by mass of HMA Specimen) 0.49 %
Moisture Content no data0 %
Temperature Compensation Factor 0.19 %
Test Temperature 538 C

Test

DIME Test ID: 2024-09-10-103-5
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 10/07/2024
Date Tested: 10/04/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: S1=150 psi, S2=143 psi, TSR=95%
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? SI Units
Average Dry Tensile Strength 150 psi
Average Wet Tensile Strength 143 psi
Tensile Strength Ratio 0.95