Print Report | Back to Sample Detail

Sample Record for 2024-06-28-119

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 212470 DEA: 044A1304 EFIS: 0400001106 COOP: 042718 QA Service Level: 1
DIST-CO-RTE-PM: 04-SON-101-18.5/18.5
Work Description: CONSISTS OF MODIFICATION AND RECONSTRUCTION OF THE EXISTING US 101/HEARN AVENUE INTERCHANGE IN SONOMA COUNTY, INCLUDING REPLACING THE EXISTING TWO-LANE HEARN AVENUE OVERCROSSING WITH A NEW OVERCROSSING, AND MODIFYING THE SOUTHBOUND OFF-RAMP IN CITY
Location Description: IN SONOMA COUNTY.
Contractor Name: Ghilotti Construction Company, Inc. (Chase McPhaul)
Contractor Address: 246 Ghilotti Avenue, Santa Rosa, CA 95407
Resident Engineer: Seyed "Syd" Valeh Structure Rep.: Anthony "Tony" Tierra; Sardar Chalabe

Sample Information

DIME Sample ID: 2024-06-28-119
TL Number from the TL Form:
Sample Submitted By Organization: Kie-Con, Incorporated - Antioch
Sample Organization Contact: (925) 331-7122
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 06/28/2024
Date that the sample was received by the laboratory/organization performing the testing: 06/28/2024
The quantity of what the sample constitutes: 80
A brief description of the sample: QC Sampling Data
From where was the sample collected: Fabricator
Laboratory sample identification: KIE CON
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: KIE CON

Material Information

The concrete mix design number: CA270-V81
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 121566
Concrete batch plant: KIE CON
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Concrete from wheelbarrow
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2024-06-28-119-1
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 10/03/2024
Date Tested: 06/28/2024
Submitted By Organization: Kie-Con, Incorporated - Antioch
Organization Address: 3551 Wilbur Avenue,
Organization City: Antioch
Organization State: CA
Organization Zipcode: 94509
Organization Email: cesar.rodriguez3@kiewit.com
Organization Phone: (925) 302-3654
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 F