Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994903 DEA: 11430244 EFIS: 1118000033
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-125-9.3/13.0
Work Description: PLACE HMA, RHMA, SLAB REPLACEMENT, AND ELECTRICAL WORK.
Location Description: SAN DIEGO COUNTY IN AND NEAR LEMON GROVE FROM 0.3 MILE SOUTH OF ELKELTON PLACE UNDERCROSSING TO 0.2 MILE SOUTH OF ROUTE 125/94 SEPARATION
Contractor Name: HAZARD CONSTRUCTION ENGR LLC
Contractor Address: 10529 Vine Street, Lakeside, CA 92040
Resident Engineer: Sultan Ghazialam Structure Rep.: Unknown
DIME Sample ID: 2024-09-29-6
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 09/29/2024
Date that the sample was received by the laboratory/organization performing the testing: 10/03/2024
The quantity of what the sample constitutes: 12 boxes
A brief description of the sample: PSU
From where was the sample collected: Source
Laboratory sample identification: 0132-PSU
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Otay
DIME Test ID: 2024-09-29-6-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 10/11/2024
Date Tested: 10/04/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies - Target 5.00% Tested 4.95% Saved Material for HMA T30
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
4027.4 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5571.5 g
|
|
Mass of HMA Sample prior to ignition
|
1544.1 g
|
|
Corrected Asphalt Binder Content
|
4.95 %
|
|
Mass Loss
|
86.2 g
|
|
Mass of aggregate remaining after ignition
|
1457.9 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.63 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|
DIME Test ID: 2024-09-29-6-2
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 10/11/2024
Date Tested: 10/04/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 2.492 , Tested 2.489
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of Samples
|
1
|
|
What is the unit of measurement for theoretical density?
|
US Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water 1
|
7475.6 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
1548.1 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8401.8 grams
|
|
Temperature of Water
|
77 °F
|
|
Specific Gravity for Sample 1
|
2.489
|
|
Theoretical maximum density at 25°C (77°F)
|
154.9 lb/ft^3
|
DIME Test ID: 2024-09-29-6-3
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 10/11/2024
Date Tested: 10/07/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 4.0% Air Voids and tested an Avg of 5.1% Air Voids
Test Result Compliance: complies
Additional Comments When Verified:
|
Percent Air Voids
|
5.1 %
|
|
Percent Air Voids 2
|
4.9 %
|
|
Percent Air Voids 3
|
5.2 %
|
|
Average Percent Air Voids
|
5.1 %
|
DIME Test ID: 2024-09-29-6-4
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 10/11/2024
Date Tested: 10/07/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 4.0% Air Voids tested an Avg of 5.1 Air Voids
Test Result Compliance: complies
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.363
|
|
Bulk Specific Gravity 2
|
2.367
|
|
Bulk Specific Gravity 3
|
2.36
|
|
Average Bulk Specific Gravity
|
2.363
|
DIME Test ID: 2024-09-29-6-5
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 10/15/2024
Date Tested: 10/15/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Average Dry Tensile Strength
|
247 psi
|
|
Average Wet Tensile Strength
|
197 psi
|
|
Tensile Strength Ratio
|
0.8
|
DIME Test ID: 2024-09-29-6-6
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Verified Date: 10/11/2024
Date Tested: 10/09/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target is <12.7 mm , Tested Avg of 1.45 mm
Test Result Compliance: complies
Additional Comments When Verified:
|
Specimen Preparation Method
|
no data
|
|
Test Temperature
|
122 F
|
|
Air Void Content for specimen A-1
|
no data
|
|
Air Void Content for specimen A-2
|
no data
|
|
Air Void Content for specimen B-1
|
no data
|
|
Air Void Content for specimen B-2
|
no data
|
|
Stripping Inflection Point (Wheel A)
|
>15000
|
|
Stripping Inflection Point (Wheel B)
|
>15000
|
|
Maximum impression at 5000 passes (left wheel)
|
1.65 mm
|
|
Maximum impression at 5000 passes (right wheel)
|
0.26 mm
|
|
Average impression at 5000 passes (left/right avg)
|
0.96 mm
|
|
Maximum impression at 10000 passes (left wheel)
|
1.98 mm
|
|
Maximum impression at 10000 passes (right wheel)
|
0.38 mm
|
|
Average impression at 10000 passes (left/right avg)
|
1.18 mm
|
|
Maximum impression at 15000 passes (left wheel)
|
2.2 mm
|
|
Maximum impression at 15000 passes (right wheel)
|
0.69 mm
|
|
Average impression at 15000 passes (left/right avg)
|
1.45 mm
|
|
Average impression at 20000 passes (left/right avg)
|
no data
|
|
Average impression at 25000 passes (left/right avg)
|
no data
|
DIME Test ID: 2024-09-29-6-7
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 10/15/2024
Date Tested: 10/11/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: 3 RAP burns
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
3983.7 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5633.4 g
|
|
Mass of HMA Sample prior to ignition
|
1649.7 g
|
|
Corrected Asphalt Binder Content
|
6.34 %
|
|
Mass Loss
|
104.6 g
|
|
Mass of aggregate remaining after ignition
|
1545.1 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
no data0 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|