Sample Record for 2024-09-28-17
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 995450 DEA: 09368004 EFIS: 0917000011
QA Service Level: 1
DIST-CO-RTE-PM: 09-MNO-395-91.6/93.4
Work Description: HOT MIX ASPHALT (TYPE A), RAIL ELEMENT WALL, AND ROADWAY EXCAVATION.
Location Description: MONO COUNTY ABOUT 16 MILES NORTH OF BRIDGEPORT FROM BURCHAM FLAT ROAD TO 0.3 MILE SOUTH OF ROUTE 108
Contractor Name: PAPICH CONSTRUCTION COMPANY, INC.
Contractor Address: Unknown
Resident Engineer: raj bharathan Structure Rep.: Unknown
Sample Information
DIME Sample ID: 2024-09-28-17
TL Number from the TL Form:
Sample Submitted By Organization: CT D09 - Bishop Field Laboratory
Sample Organization Contact: (760) 872-5211
Type of Sample: Quality Assurance
Type of Material: Aggregate
Sample Taken Date: 09/28/2024
Date that the sample was received by the laboratory/organization performing the testing: 09/30/2024
The quantity of what the sample constitutes: 750 Tons
A brief description of the sample: 3/4" Coldfeed & RAP
From where was the sample collected: Source
Laboratory sample identification: CF-21
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Lee Vining Plant
Material Information
Source Identification (SMARA, name of Pit or Job Site): 00-00-0000
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Sample Device at Hot Plant
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:
Test Results
Test 1 of 2
DIME Test ID: 2024-09-28-17-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 10/07/2024
Date Tested: 09/30/2024
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: CF-21 Agg
Test Result Compliance: complies
Additional Comments When Verified:
|
What type of gradation is being tested?
|
HMA Gradation
|
|
Cumulative percent passing the 2 in. sieve
|
no data
|
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
|
Cumulative percent passing the 3/4 in. sieve
|
94.5 %
|
|
Cumulative percent passing the 1/2 in. sieve
|
77.8 %
|
|
Cumulative percent passing the 3/8 in. sieve
|
71.2 %
|
|
Cumulative percent passing the #4 sieve
|
52.8 %
|
|
Cumulative percent passing the #8 sieve
|
36.7 %
|
|
Cumulative percent passing the #16 sieve
|
24.9 %
|
|
Cumulative percent passing the #30 sieve
|
18.2 %
|
|
Cumulative percent passing the #50 sieve
|
11.9 %
|
|
Cumulative percent passing the #100 sieve
|
7.1 %
|
|
Cumulative percent passing the #200 sieve
|
3.9 %
|
Test 2 of 2
DIME Test ID: 2024-09-28-17-2
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 10/07/2024
Date Tested: 09/30/2024
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: CF-21 RAP
Test Result Compliance: complies
Additional Comments When Verified:
|
Is an aggregate correction factor used?
|
Yes
|
|
Aggregate correction factor for the 2 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 1 1/2 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 1 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 3/4 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 1/2 in. sieve (% passing)
|
no data0 %
|
|
Aggregate correction factor for the 3/8 in. sieve (% passing)
|
-0.1 %
|
|
Aggregate correction factor for the #4 sieve (% passing)
|
5.2 %
|
|
Aggregate correction factor for the #8 sieve (% passing)
|
2.3 %
|
|
Aggregate correction factor for the #16 sieve (% passing)
|
-1.1 %
|
|
Aggregate correction factor for the #30 sieve (% passing)
|
-5.6 %
|
|
Aggregate correction factor for the #50 sieve (% passing)
|
-4.2 %
|
|
Aggregate correction factor for the #100 sieve (% passing)
|
-2.2 %
|
|
Aggregate correction factor for the #200 sieve (% passing)
|
-1.3 %
|
|
Cumulative percent passing the 2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
|
Cumulative percent passing the 3/4 in. sieve
|
100 %
|
|
Cumulative percent passing the 1/2 in. sieve
|
100 %
|
|
Cumulative percent passing the 3/8 in. sieve
|
100 %
|
|
Cumulative percent passing the #4 sieve
|
73 %
|
|
Cumulative percent passing the #8 sieve
|
48 %
|
|
Cumulative percent passing the #16 sieve
|
31 %
|
|
Cumulative percent passing the #30 sieve
|
18 %
|
|
Cumulative percent passing the #50 sieve
|
12 %
|
|
Cumulative percent passing the #100 sieve
|
10 %
|
|
Cumulative percent passing the #200 sieve
|
7 %
|