Print Report | Back to Sample Detail

Sample Record for 2024-09-27-36

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993870 DEA: 120R5604 EFIS: 1218000117 QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-5,55,73,91,133,405-var
Work Description: PLACE RHMA-G, HMA, SLAB REPLACEMENT AND JPCP.
Location Description: ORANGE COUNTY AT VARIOUS LOCATIONS
Contractor Name: SECURITY PAVING COMPANY INC.
Contractor Address: 3075 Towngate Road, St. 200, Westlake Village, CA 91361
Resident Engineer: Roy Rivera Structure Rep.: Vian Ghazi

Sample Information

DIME Sample ID: 2024-09-27-36
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Production Start-Up
Type of Material: Hot Mix Asphalt
Sample Taken Date: 09/27/2024
Date that the sample was received by the laboratory/organization performing the testing: 10/01/2024
The quantity of what the sample constitutes: 22 BX HMA 3 QT PG 64-10 2 BG CMB AGG 1 BG RAP
A brief description of the sample: 3/4" HMA A SP R15 NO LAS
From where was the sample collected: Manufacturer
Laboratory sample identification: 0506A-24
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: AAA-Corona

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: 105793
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 4

DIME Test ID: 2024-09-27-36-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 12/17/2024
Date Tested: 10/04/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? SI Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 7351.3 grams
Mass of oven-dry sample in air for Sample 1 2555.7 grams
Mass of container filled with the sample and water for Sample 1 8899.9 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.538
Theoretical maximum density at 25°C (77°F) 2530.6 kg/m^3

Test 2 of 4

DIME Test ID: 2024-09-27-36-2
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 12/17/2024
Date Tested: 10/05/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids 4.1 %
Percent Air Voids 2 3.9 %
Percent Air Voids 3 3.9 %
Average Percent Air Voids 4 %

Test 3 of 4

DIME Test ID: 2024-09-27-36-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 12/17/2024
Date Tested: 10/05/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Bulk Specific Gravity 2.435
Bulk Specific Gravity 2 2.439
Bulk Specific Gravity 3 2.438
Average Bulk Specific Gravity 2.437

Test 4 of 4

DIME Test ID: 2024-09-27-36-4
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 12/17/2024
Date Tested: 10/04/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of HMA Sample prior to ignition 2114 g
Corrected Asphalt Binder Content 4.71 %
Mass Loss 107.7 g
Correction Factor (Percent by mass of HMA Specimen) 0.26 %
Moisture Content no data0 %
Temperature Compensation Factor 0.13 %
Test Temperature 538 C