Print Report | Back to Sample Detail

Sample Record for 2024-09-19-62

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995055 DEA: 024H0504 EFIS: 0218000080 QA Service Level: 1
DIST-CO-RTE-PM: 02-SHA-273,299-18.5/18.7,24.1/30.3
Work Description: PLACE RHMA, HMA, MINOR CONCRETE, AND REPLACE AC SURFACING.
Location Description: SHASTA COUNTY IN AND NEAR REDDING ON ROUTE 273 FROM 0.5 MILE NORTH OF SULPHUR CREEK BRIDGE TO 0.2 MILE SOUTH OF TWIN VIEW BOULEVARD AND ON ROUTE 299 FROM 0.2 MILE WEST OF HILLTOP DRIVE TO 0.1 MILE EAST OF HOOTENANNY LANE
Contractor Name: TULLIS, INC.
Contractor Address: 16951 Clear Creek Road, Redding, CA 96001
Resident Engineer: Nathan Alexander Structure Rep.: Nicolas Jimenez

Sample Information

DIME Sample ID: 2024-09-19-62
TL Number from the TL Form: 858514
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Production Start-Up
Type of Material: Hot Mix Asphalt
Sample Taken Date: 09/19/2024
Date that the sample was received by the laboratory/organization performing the testing: 09/23/2024
The quantity of what the sample constitutes: 2 Gal Cans
A brief description of the sample: 1/2" OGFC
From where was the sample collected: Manufacturer
Laboratory sample identification: D79720
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Tullis Inc. - Northstate Asphalt (Redding CA)

Material Information

HMA Type: OGFC
HMA Grading: 1/2 inch
Lot number:
Sublot number:
HMA Mix Number:
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 1

DIME Test ID: 2024-09-19-62-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 09/26/2024
Date Tested: 09/25/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Pb=7.19
Test Result Compliance: does not comply
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 3112.1 g
Mass of the specimen and specimen basket assembly prior to ignition 4767.8 g
Mass of HMA Sample prior to ignition 1655.7 g
Corrected Asphalt Binder Content 7.2 %
Mass Loss 128.9 g
Mass of aggregate remaining after ignition 1526.8 g
Correction Factor (Percent by mass of HMA Specimen) 0.41 %
Moisture Content no data0 %
Temperature Compensation Factor 0.18 %
Test Temperature 538 C