Print Report | Back to Sample Detail

Sample Record for 2024-08-28-94

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995057 DEA: 07321604 EFIS: 0716000049 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-1-0.0/18.0
Work Description: COLD PLANE AND OVERLAY AC PAVEMENT AND UPGRADE ADA CURB RAMPS.
Location Description: LOS ANGELES COUNTY FROM STUDEBAKER ROAD TO PASEO DE LAS DELICIAS
Contractor Name: R.J. NOBLE COMPANY
Contractor Address: 15505 E. Lincoln Ave, Orange, CA 92865
Resident Engineer: Thang Ton Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-08-28-94
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 08/28/2024
Date that the sample was received by the laboratory/organization performing the testing: 09/20/2024
The quantity of what the sample constitutes: 1can
A brief description of the sample: Asphalt Rubber Binder
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: R.J. Noble-Corona

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2024-08-28-94-1
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 09/27/2024
Date Tested: 09/25/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
ASTM Thermometer used? C
Softening Point Sample 1 58 C
Softening Point Sample 2 58 C
Bath Liquid freshly boiled distilled water
Minutes Reaction no data

Test 2 of 3

DIME Test ID: 2024-08-28-94-2
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 09/27/2024
Date Tested: 09/25/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Determination Unworked Penetration
Unworked Penetration 41 0.1 mm

Test 3 of 3

DIME Test ID: 2024-08-28-94-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 09/27/2024
Date Tested: 09/25/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 25 C
Ball Penetration (P1) 7 mm
Final Dial reading (F1) 86 mm
Ball Penetration (P2) 3 mm
Final Dial reading (F2) 70 mm
Ball Penetration (P3) 3 mm
Final Dial reading (F3) 73 mm
Resilience 1 21 %
Resilience 2 33 %
Resilience 3 30 %
Average Resilience 32 %
Minutes Reaction no data