REPORT OF LABORATORY TESTING |
||||
|
Resident Engineer: |
Eddie Dike |
Date Reported: |
09/25/2024 |
|
|
Address: |
TL Number: |
|
||
|
City: |
||||
|
Project Name: Repair Slip Out |
||||
|
Prime Contractor: Pacific Coast Drilling Co., Inc. (Aaron Sykes) |
||||
|
Sample Taken Date: |
08/28/2024 |
Mix Design: |
DDJ118E3 |
|
|
Contractor: Unknown |
Location : Niles Canyon |
|||
|
Structure unique identifier: 33-0776 |
||||
|
Structure name: Alameda Creek Bridge |
||||
|
Location of Pour: CIDH Pile for Pier 1R |
||||
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
| Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
|---|---|---|---|---|---|
| 1 | 4.02 | 12.69 | 62274 | 4906.0 | 1 |
| 2 | 4.01 | 12.63 | 66114 | 5235.0 | 1 |
| 3 | 4.00 | 12.57 | 64679 | 5147 | 1 |
DIME Test ID: 2024-08-28-86-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 5100
Age of specimen: 28 days
Certified By: Spencer Adams
|
*Subject to final inspection by the Resident Engineer. |
|
TL- Report of Laboratory Testing