Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994869 DEA: 073237U4 EFIS: 0720000224
QA Service Level: 1
DIST-CO-RTE-PM: 07-VEN-150-13.3/19
Work Description: PLACE HMA (TYPE A) AND COLD PLANE ASPHALT
Location Description: VENTURA COUNTY IN AND NEAR OJAI FROM BURNHAM ROAD TO GORHAM ROAD
Contractor Name: C. A. RASMUSSEN INC.
Contractor Address: 28548 Livingston Ave., Valencia, CA, 91355
Resident Engineer: Denrick Bautista Structure Rep.: Unknown
DIME Sample ID: 2024-09-10-80
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Production Start-Up
Type of Material: Hot Mix Asphalt
Sample Taken Date: 09/10/2024
Date that the sample was received by the laboratory/organization performing the testing: 09/19/2024
The quantity of what the sample constitutes: 20 BX HMA 4 QT PG58-16 1 QT LAS 4 BG CMB AGG 2 BG RAP
A brief description of the sample: 3/4" HMA A SP R25 .5%LAS
From where was the sample collected: Manufacturer
Laboratory sample identification: 0486A-24
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: vulcan saticoy
DIME Test ID: 2024-09-10-80-1
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 12/11/2024
Date Tested: 09/24/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Number of Samples
|
1
|
|
What is the unit of measurement for theoretical density?
|
SI Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water 1
|
7327.1 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
2563.7 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8865.1 grams
|
|
Temperature of Water
|
77 °F
|
|
Specific Gravity for Sample 1
|
2.499
|
|
Theoretical maximum density at 25°C (77°F)
|
2492 kg/m^3
|
DIME Test ID: 2024-09-10-80-2
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 12/11/2024
Date Tested: 09/25/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Percent Air Voids
|
3.6 %
|
|
Percent Air Voids 2
|
3.3 %
|
|
Percent Air Voids 3
|
3.5 %
|
|
Average Percent Air Voids
|
3.5 %
|
DIME Test ID: 2024-09-10-80-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 12/11/2024
Date Tested: 09/25/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.409
|
|
Bulk Specific Gravity 2
|
2.416
|
|
Bulk Specific Gravity 3
|
2.412
|
|
Average Bulk Specific Gravity
|
2.412
|
DIME Test ID: 2024-09-10-80-4
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 12/11/2024
Date Tested: 09/26/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
SI Units
|
|
Average Dry Tensile Strength
|
161 psi
|
|
Average Wet Tensile Strength
|
135 psi
|
|
Tensile Strength Ratio
|
84
|
DIME Test ID: 2024-09-10-80-5
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 12/11/2024
Date Tested: 09/24/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of HMA Sample prior to ignition
|
2162 g
|
|
Corrected Asphalt Binder Content
|
4.93 %
|
|
Mass Loss
|
118.3 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.4 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.14 %
|
|
Test Temperature
|
538 C
|
DIME Test ID: 2024-09-10-80-6
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Verified Date: 12/11/2024
Date Tested: 09/27/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A)
|
15000
|
|
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B)
|
15000
|
|
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A)
|
3.74 mm
|
|
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B)
|
3.32 mm
|
|
Stripping Inflection Point (Wheel A)
|
25000
|
|
Stripping Inflection Point (Wheel B)
|
25000
|