Sample Record for 2024-07-31-116
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 994582 DEA: 073203U4 EFIS: 0722000071
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-91,605-R16.6/R16.8,R0.0/R10.4
Work Description: PLACE CONCRETE PAVEMENT AND HIGH FRICTION SURFACE TREATMENT.
Location Description: LOS ANGELES COUNTY ON ROUTE 605 FROM 0.2 MILE NORTH OF KATELLA AVENUE UNDECROSSING TO 0.1 MILE NORTH OF TELEGRAPH ROAD UNDERCROSSING AND ON ROUTE 91 FROM 0.4 MILE WEST OF ROUTE 605 UNDERCROSSING TO 0.2 MILE WEST OF ROUTE 605 UNDERCROSSING
Contractor Name: RASMUSSEN/VANGUARD
Contractor Address: 28548 LIVINGSTON AVENUE, VALENCIA CA 91335
Resident Engineer: Martin Oregel Structure Rep.: Tien Chu
Sample Information
DIME Sample ID: 2024-07-31-116
TL Number from the TL Form:
Sample Submitted By Organization: CT D07 - Plant Services
Sample Organization Contact: 562-345-3126
Type of Sample: Acceptance
Type of Material: Aggregate
Sample Taken Date: 07/31/2024
Date that the sample was received by the laboratory/organization performing the testing: 08/05/2024
The quantity of what the sample constitutes: 160 tons
A brief description of the sample: 3/4 HMA-A
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Irwindale
Material Information
Source Identification (SMARA, name of Pit or Job Site): 91-19-0035
The fabricator's/manufacturer's product name for the sample: 3/4 HMA-A
The fabricator/manufacturer designation for the sample:
The plant number: Irwindale
A detailed description of where the material sample was collected: Belt Discharge
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number: 220992M IRW VLO
Lot number:
Sublot number:
Aggregate Mix Number:
Test Results
Test 1 of 3
DIME Test ID: 2024-07-31-116-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 11/15/2024
Date Tested: 08/06/2024
Submitted By Organization: CT D07 - Plant Services
Organization Address: 13230 East Firestone Boulevard, Suite G,
Organization City: Santa Fe Springs
Organization State: CA
Organization Zipcode: 90670
Organization Email: victor.zengler@dot.ca.gov
Organization Phone: (562) 345-3126
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
|
What type of gradation is being tested?
|
Combined Gradation
|
|
Cumulative percent passing the 2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
|
Cumulative percent passing the 3/4 in. sieve
|
96 %
|
|
Cumulative percent passing the 1/2 in. sieve
|
84 %
|
|
Cumulative percent passing the 3/8 in. sieve
|
75 %
|
|
Cumulative percent passing the #4 sieve
|
49 %
|
|
Cumulative percent passing the #8 sieve
|
36 %
|
|
Cumulative percent passing the #16 sieve
|
25 %
|
|
Cumulative percent passing the #30 sieve
|
15 %
|
|
Cumulative percent passing the #50 sieve
|
9 %
|
|
Cumulative percent passing the #100 sieve
|
7 %
|
|
Cumulative percent passing the #200 sieve
|
4.5 %
|
Test 2 of 3
DIME Test ID: 2024-07-31-116-2
Test Method: AASHTO T11-5: Standard Method of Test for Materials Finer Than 75-μm (No. 200) Sieve in Mineral Aggregates by Washing
Verified Date: 11/15/2024
Date Tested: 08/06/2024
Submitted By Organization: CT D07 - Plant Services
Organization Address: 13230 East Firestone Boulevard, Suite G,
Organization City: Santa Fe Springs
Organization State: CA
Organization Zipcode: 90670
Organization Email: victor.zengler@dot.ca.gov
Organization Phone: (562) 345-3126
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Which test procedure is being used
|
Method A
|
|
Percent of sample passing the #200 sieve (by mass)
|
12 %
|
Test 3 of 3
DIME Test ID: 2024-07-31-116-3
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 11/15/2024
Date Tested: 08/06/2024
Submitted By Organization: CT D07 - Plant Services
Organization Address: 13230 East Firestone Boulevard, Suite G,
Organization City: Santa Fe Springs
Organization State: CA
Organization Zipcode: 90670
Organization Email: victor.zengler@dot.ca.gov
Organization Phone: (562) 345-3126
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified: