Print Report | Back to Sample Detail

Sample Record for 2024-09-12-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000165 DEA: 09392504 EFIS: 0923000029 QA Service Level: 1
DIST-CO-RTE-PM: 09-INY-395-R17.2/25.8
Work Description: HOT MIX ASPHALT (TYPE A), SHOULDER BACKING, & STRIPING.
Location Description: INYO COUNTY ABOUT 9 MILES SOUTH OF OLANCHA FROM 0.8 MILE SOUTH OF SYKES ROAD TO 0.3 MILE NORTH OF HAIWEE CANYON ROAD
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 8999 Capacity Street, Arvin, CA 93203
Resident Engineer: Garret Rottner Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-09-12-3
TL Number from the TL Form:
Sample Submitted By Organization: CT D09 - Bishop Field Laboratory
Sample Organization Contact: (760) 872-5211
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 09/12/2024
Date that the sample was received by the laboratory/organization performing the testing: 09/12/2024
The quantity of what the sample constitutes: 1 box 1 core
A brief description of the sample: 3/4” HMA core
From where was the sample collected: Job Site
Laboratory sample identification: Core 3C
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Solari Plant

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number:

Test Results

Test 1 of 2

DIME Test ID: 2024-09-12-3-1
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 09/13/2024
Date Tested: 09/13/2024
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: Density CR-3C= 93.3% Re-Cored Dig Outs after Dig Outs were re-Paved
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids 6.7 %

Test 2 of 2

DIME Test ID: 2024-09-12-3-2
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 09/13/2024
Date Tested: 09/13/2024
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: Core 3A Re-cored Dig Outs after repaving of Dig Outs
Test Result Compliance: complies
Additional Comments When Verified:
Bulk Specific Gravity 2.363