Combined Gradation Report
Report Name: HMA Aggregates (Size 3/4"): Type A HMA - Continuous Mixing Plant - Sieve Analysis With RAP
Report ID: Combined Gradation-2024-06-31
Specification: 2023 Caltrans Standard Specification - Type A HMA 3/4 inch
Subsample Material DIME Sample ID Test Method Percentage Other |
1 Aggregate 2024-06-11-60 AASHTO T27-14 Percentage 75 % | 2 Aggregate 2024-06-11-59 AASHTO T30-19 Percentage 25 % |
Combined Gradation 100 % |
Target Value |
Specification Limits (Target Value ± Tolerance) | ||
Sieve Size |
% PASS | % USED | % PASS | % USED |
% PASS
|
% PASS |
% PASS |
2" |
100 | 75 | 100 | 25 | 100 | 100 | - |
1½" |
100 | 75 | 100 | 25 | 100 | 100 | - |
1" |
100 | 75 | 100 | 25 | 100 | 100 | 100 - 100 |
¾" |
94 | 71 | 99 | 25 | 96 | 91 | 86 - 96 |
½" |
75 | 56 | 83 | 21 | 77 | 77 | 71 - 83 |
⅜" |
66 | 50 | 74 | 19 | 69 | 70 | - |
No. 4 |
41 | 31 | 55 | 14 | 45 | 44 | 39 - 49 |
No. 8 |
29 | 22 | 46 | 12 | 34 | 29 | 24 - 34 |
No. 16 |
22 | 17 | 35 | 9 | 26 | 21 | - |
No. 30 |
16 | 12 | 26 | 7 | 19 | 15 | 11 - 19 |
No. 50 |
11 | 8 | 17 | 4 | 12 | 10 | - |
No. 100 |
7 | 5 | 10 | 3 | 8 | 6 | - |
No. 200 |
4.2 | 3.2 | 5 | 1.3 | 4.5 | 3.3 | 1.3 - 5.3 |
General comments |
CF-R114 |
CF-R113 RAP |
Gradation By: Derek Carrington
Report Comment: CF-R114
Published By: Derek Carrington
Published Date: 2024-06-12
Published Comment: CF-R114
Report Comment: CF-R114
Published By: Derek Carrington
Published Date: 2024-06-12
Published Comment: CF-R114